This website requires JavaScript.
Explore
Help
Sign In
parouby
/
acoused
Watch
1
Star
0
Fork
0
mirror of
https://forgemia.inra.fr/theophile.terraz/acoused.git
synced
2026-10-30 03:10:40 +01:00
Code
Issues
Packages
Projects
Releases
Activity
Files
1b2c5954ee563e871a9ef7b6f0d03dfe751a3a20
acoused
/
View
T
History
brahim
1b2c5954ee
Vertical profile plot of SSC sand is added and a red vertical line display the profile position 2D field. Measured vs Inverted SSC sand is added. User can choose sample to display.
2024-08-30 20:41:12 +02:00
..
__init__.py
First commit of View file
2023-07-27 12:07:40 +02:00
acoustic_data_tab.py
FCB computatuion and display are added on sediment calibration tab. By default, the position of the FCB vertical profile is set on the profile position of calibration samples. The user can choose the depth limits to fit the FCB profile with linear regression. The FCB profile is diplay on acoustic recording 2D field.
2024-08-26 11:19:25 +02:00
acoustic_inversion_tab.py
Vertical profile plot of SSC sand is added and a red vertical line display the profile position 2D field. Measured vs Inverted SSC sand is added. User can choose sample to display.
2024-08-30 20:41:12 +02:00
checkable_combobox.py
Investigations with inversion method (for high concentrations) have been performed with APAVER 2021 data from UBSediFlow system.
2024-01-12 16:20:08 +01:00
mainwindow.py
A context menu is added. Update Table for Save action created.
2024-06-03 15:26:09 +02:00
note_tab.py
Acoustic inversion method for high concentration is implemented. It is tested with Aquascat data acquired during Adrien PhD (Confluence Rhône-Isère, 2018.01.07)
2023-11-28 15:42:29 +01:00
sample_data_tab.py
The sediment calibration tab includes plot of acoustic recordings and profile of the concentration of fine sediments. The user can choose the data, frequencies and select the samples for the calibration.
2024-07-19 17:46:44 +02:00
sediment_calibration_tab.py
FCB computatuion and display are added on sediment calibration tab. By default, the position of the FCB vertical profile is set on the profile position of calibration samples. The user can choose the depth limits to fit the FCB profile with linear regression. The FCB profile is diplay on acoustic recording 2D field.
2024-08-26 11:19:25 +02:00
signal_processing_tab.py
Signal processing tab is completely reorganized. At the top from the left to the right : 1 - choice of acoustic recording data + noise data, 2 - Display the SNR plot, 3 - Display option (SNR, Rayleigh, Average). At the bottom, from the left to the right : 1 - plot pre-processed BS acoustic recording, 2 - Plot profil, 3 - List of preprocessed data
2024-08-29 15:45:43 +02:00
user_manual_tab.py
First commit of View file
2023-07-27 12:07:40 +02:00