acoused/View
brahim ffc85d733d Signal processing tab is completely reorganized. At the top from the left to the right : 1 - choice of acoustic recording data + noise data, 2 - Display the SNR plot, 3 - Display option (SNR, Rayleigh, Average). At the bottom, from the left to the right : 1 - plot pre-processed BS acoustic recording, 2 - Plot profil, 3 - List of preprocessed data 2024-08-29 15:45:43 +02:00
..
__init__.py First commit of View file 2023-07-27 12:07:40 +02:00
acoustic_data_tab.py FCB computatuion and display are added on sediment calibration tab. By default, the position of the FCB vertical profile is set on the profile position of calibration samples. The user can choose the depth limits to fit the FCB profile with linear regression. The FCB profile is diplay on acoustic recording 2D field. 2024-08-26 11:19:25 +02:00
acoustic_inversion_tab.py Acoustic inversion tab display results of the inversion computation for both, fine and sand sediments. The user can visualize the concentrations fields, plot vertical profiles of the concentrations and choose samples to compare measured SSC vs inverted SSC. 2024-08-21 09:26:08 +02:00
checkable_combobox.py Investigations with inversion method (for high concentrations) have been performed with APAVER 2021 data from UBSediFlow system. 2024-01-12 16:20:08 +01:00
mainwindow.py A context menu is added. Update Table for Save action created. 2024-06-03 15:26:09 +02:00
note_tab.py Acoustic inversion method for high concentration is implemented. It is tested with Aquascat data acquired during Adrien PhD (Confluence Rhône-Isère, 2018.01.07) 2023-11-28 15:42:29 +01:00
sample_data_tab.py The sediment calibration tab includes plot of acoustic recordings and profile of the concentration of fine sediments. The user can choose the data, frequencies and select the samples for the calibration. 2024-07-19 17:46:44 +02:00
sediment_calibration_tab.py FCB computatuion and display are added on sediment calibration tab. By default, the position of the FCB vertical profile is set on the profile position of calibration samples. The user can choose the depth limits to fit the FCB profile with linear regression. The FCB profile is diplay on acoustic recording 2D field. 2024-08-26 11:19:25 +02:00
signal_processing_tab.py Signal processing tab is completely reorganized. At the top from the left to the right : 1 - choice of acoustic recording data + noise data, 2 - Display the SNR plot, 3 - Display option (SNR, Rayleigh, Average). At the bottom, from the left to the right : 1 - plot pre-processed BS acoustic recording, 2 - Plot profil, 3 - List of preprocessed data 2024-08-29 15:45:43 +02:00
user_manual_tab.py First commit of View file 2023-07-27 12:07:40 +02:00